DCI Prologis, Brooklands, Weybridge
ARCHITECT
Stephen George and Partners
CONTRACTOR
Winvic Construction
WINDOW SUB-CONTRACTOR
Ardent Glazing
DESCRIPTION
EI 60 Fixed Glazed Lights
Project Analysis
EI60 Fire Resisting Glazed Lights
The fire resisting glazing fitted to the first floor had a requirement to provide EI 60 (integrity and insulation). One of the fixed lights is over four metres long, and the architect and client wanted as much glass as possible with minimum framing.
The Solution
Products used for this project
Aluprof MB 78 EI glazed fixed lights in a powder coated anthracite finish, are glazed with 35mm thick Polflam glass. To achieve the required aesthetics, the glass does not have mullions between the panes, but are glazed with fire resisting silicone butt joints in the vertical plane.